Details
The BLU-GPX features the same rich palette of Logic Objects found in other Soundweb London devices, two PoE-enabled Ethernet ports for communications and primary power, a 12VDC power connector for secondary power, a RS-232 port for compatibility with serial devices, a bank of user-configurable front panel LEDs, a user-configurable front panel LCD, a user-configurable piezo buzzer for audible indication, and locate functionality.
The BLU-GPX has 36 Control Inputs. As with the Control Inputs found on other Soundweb London devices, these Control Inputs can be connected to contact closures for controlling binary parameters, resistor ladders for controlling multi-state parameters, or potentiometers for controlling continuous parameters.
The BLU-GPX has 23 Logic Outputs. As with the Logic Outputs found on other Soundweb London devices, these Logic Outputs can be connected directly to voltage-controlled electrical components such as LEDs and relays.
The BLU-GPX has 8 integrated Relay Outputs, each with Normally Open (NO) and Normally Closed (NC) terminals. The Relays will open or close in response to HiQnet parameters, and they can be connected directly to resistance-controlled electrical components/circuits. These Relay Outputs reduce the need to source and deploy external relays.
The BLU-GPX has 47 Common (ground) connections. A multiplicity of Common connections results in simplified wiring to and from external equipment, reducing the need to span connections across terminal block connectors. Also provided are 12 Reference connections which facilitate 3-wire mode operation.