| Model | XLS 1500 |
| Product Type | Power Amplifier |
| 1 kHz Power 2Ω Dual (per channel) | 775W |
| 1 kHz Power 4Ω Dual (per channel) | 525W |
| 1 kHz Power 8Ω Dual (per channel) | 300W |
| 1 kHz Power 8Ω Bridge | 1,050W |
| 1 kHz Power 4Ω Bridge | 1,550W |
| Performance | Specifications |
| Sensitivity (for full rated power at 4 ohms) | 1.4 Vrms |
| Frequency Response (at 1 watt, 20 Hz to 20 kHz) | +0 dB, –1 dB |
| Signal-to-Noise Ratio Rated as dBr to full rated 8 ohm power output (A-Weighted) | > 103 dB |
| Total Harmonic Distortion (THD) | < 0.5% |
| Intermodulation Distortion (IMD) | (60 Hz and 7 kHz at 4:1)
from full rated output to –30 dB: < 0.3% |
| Damping Factor (8 ohm) 10 Hz to 400 Hz | >200 |
| Crosstalk (below rated 8 ohm power) | At 1kHz: > 85dB
At 20kHz: >55dB |
| Input Impedance (nominal) | 20 kilohms balanced, 10 kilohms unbalanced |
| Load Impedance | 2 to 8 ohms per channel in Stereo, 4 to 8 ohms in Bridge Mono |
| AC Line Voltage and Frequency Configurations Available (±10%) | 120 VAC 60 Hz, 100 VAC 50/60 Hz, 220 and 240 VAC 50 Hz |
| Controls | Specifications |
| Level | Two front-panel rotary level controls, one for each channel |
| LCD Screen | Backlit LCD allows for crossover configuration, amp
mode configuration clip compressor configuratio |
| Menu/Prev/Next | Buttons located near the LCD screen that are
used to configure and access the integrated processing |
| Power | Front-panel switch; on when in the IN position. Blue LED will
illuminate when on |
| Circuit Breaker | Back-panel breaker provides overload protection |
| Integrated Processing PureBand™ Crossover System | Specifications |
| Crossover Filter | Linkwitz-Riley 24dB per octave |
| Crossover Frequency Range | 50 Hz - 3 kHz |
| Crossover Mode | Crossover (CH1=LPF, CH2=HPF), Low Pass
(both channels LPF), High Pass (both HPF)
Bridge (LPF or HP |
| Peak Limiters | Channel independent clip limiter designed to provide maximum output |
| Signal Presence Indicators | Two green LEDs, one for each channel,
illuminate when the channel’s input signal exceeds –40 dBu |
| 10 Indicator | Green LED flashes when output signal exceeds –10 dB below clip |
| 20 Indicator | Green LED flashes when output signal level exceeds
–20 dB below clip |
| Clip Indicators | Two red LEDs, one for each channel, illuminate when
the channel’s output is being overdriven |
| Thermal Indicator | Two red LEDs, one for each channel, illuminate
when thermal compression begins |
| Input/Output | Specifications |
| Input Connectors | XLR (one per channel), 1/4 inch (one per channel),
and RCA (one per channel) |
| Output Connectors | Two 4-Pole Speakon® Output Connectors
accept 2-pole or 4-pole Speakon® connectors |
| Protection | DC protection, circuit
breaker, and thermal protection |
| Construction | Specifications |
| Ventilation | Flow-through ventilation from front to back |
| Cooling | Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation |
| Cooling | Internal heat sinks with forced-air cooling for rapid, uniform heat dissipation |
| Air Volume Requirements (per minute per unit) | 80.15 ft3 (2.27 m3) |
| Dimensions | EIA Standard 19-inch (48.3cm) rack mount W x (EIA RS-310-B), 3.5-inch(8.9cm) H x 7.7-inch (19.6cm) D |
| Net Weight | 8.6 lbs (3.9 kg) |
| Shipping Weight | 13.6 lbs (6.2 kg) |
| |
 |
 |