Skip to main content

Ashly Audio nXe8004 4-Channel 800W Networkable Power Amplifier with Ethernet Control

Part #:
nXe8004
Model #:
nXe8004
Availability: Usually arrives in 5-9 business days. Please be aware that global supply shortages outside our control may interfere with our normal delivery times and product availability. For more information, email sales@proacoustics.com or call us at 888-256-4112.
Certified Audio
Expertise
FREE Custom
System Design
Get Expert
Help Fast

Ask an Expert

Our expertly trained Sales Engineers are ready to help!

(888) 256-4112

Get a Quote, Price or Support Fast!

We want to make contacting us as fast and as easy as possible. Please reach out if you have any questions or concerns about our products, system design, technical support, or orders.
Phone Monday - Friday
8:00 AM - 5:00 PM
1-888-256-4112
Email Contact us by email or
our simple form.
SEND EMAIL

The Ashly nXe8004 is a 4-channel networkable power amplifier. It features lightweight, energy-efficient Class-D switching amplifier technology combined with a switch mode power supply and includes Ethernet Control using Protea™ NE software.

Description

NX Multi-Mode Power Amplifiers are designed to meet the most demanding live sound environments and fixed audio installations anywhere―performance venues, stadiums, arenas, convention centers as well as schools, store fronts, and worship spaces. Available as three separate amplifier series, NX offers 2 or 4-channel models as NX (base model series), NXE (networkable), or NXP (networkable + DSP).

All NXE Models Include:

Ethernet Control using Protea™ NE software 
Also, serial data control by Ashly programmable remotes or third party controllers, aux preamp outputs, instant standby mode, preset recall, fault condition logic outputs, optional Dante™, CobraNet™, or AES3 digital audio capability (factory-installed). Real-Time Clock with Event Scheduler. Assign automatic execution of selected functions and tasks. The event scheduler is programmed using PneS software and stored in the amplifier. Ashly Remote Control via iPad® app. Use our Ashly Remote free app available for custom design of secure wireless control over a network.

Class-D Switching Amplifier Technology 
NXE features a switch-mode power supply which automatically detects 110 – 120VAC or 220 – 240VAC operation and makes NXE one of the lightest in its class.

Multi-Mode Operation 
Selectable Outputs on each channel allow you to choose the desired output mode. Set the DIP-switch configuration for Low Impedance (2, 4, and 8 Ohm), or Constant Voltage (70V or 100V) and you’re set to go.

Energy Efficiency 
NXE has power-saving Ashly EMS™ (Energy Management System) which provides an automatic sleep-mode drawing less than 1 Watt (defeatable).

Multiple Internal Power Supplies
NXE provides increased channel separation and reliability.

Features

  • Selectable 80Hz Hipass filter, limiter, and input gain per channel, via rear panel
  • Remote DC level control per channel
  • Extensive protection circuitry, continuously variable cooling fans
  • Ethernet port for software control and monitoring of amplifier functions, with front panel COM activity LED
  • Serial data port available for Ashly WR-5 and RD-8C programmable remote control (optional RS-232 converter INA-1 available for third party controllers)
  • Instant Standby Mode, 30% reduction in idle power consumption, triggered by contact closure, software control, or event scheduler
  • Preset recall via contact closure, software control, remote control, or event scheduler
  • Programmable power-on delay
  • Aux preamp line outputs for driving other amplifiers
  • Fault condition logic outputs, per channel
  • Neutrik® Combo XLR – 1/4” TRS jack plus Euroblock input connectors
  • Neutrik® speakON® twist locking loudspeaker connectors
  • Neutrik® powerCON® detachable AC mains connector
  • Safety/Compliance: cTUVus, CE, FCC, RoHS

Specifications

Channels 4
Max Output Power Measured in Watts, Per Channel, Low-Z Output, All Channels Driven
2/4/8 Ohms 800
Low Z Output Measured in Watts, Bridge Mode, All Channels Driven
4/8 Ohms 1600
70V, 100V Output Measured in Watts, All Channels Driven
70V (per channel); 100V (per channel) 800
Total Power Draw, Measured in Watts Total for all Channels
Sleep Mode < 1
Standby Mode 40
Idle (no signal) 70
Current Draw Measured in Amps, Total for all Channels, 120VAC, Divide by 2 for 240V
Sleep Mode 0.1
Standby Mode 0.70
Idle (no signal) 1.30
Max Current Draw Measured in Amps, Typical Input, All Channels Driven, Divide by 2 for 240V
1/8 Max Power @ 2 Ohms 8.8
Thermal Dissipation BTU/hr, Typical Input, Total for all Channels
Sleep Mode < 3.4
Standby Mode 136
Idle (no signal) 238
1/8 Max Power @ 2 Ohms 970
Voltage Gain Selectable at 26dB, 32dB, 38dB, or 1.4V
Damping Factor >250 (8 Ohms load
Input High Pass Filter 80Hz 2nd order
Distortion (SMPTE, typical)
Distortion (THD-N, typical)
Channel Separation -75dB (dB from full output, 1kHz)
Signal-to-Noise (20Hz–20kHz, unweighted) >108dB
Frequency Response 20Hz–20kHz, +/-0.05dB
Balanced Input Connector Euroblock 3.5mm, 1/4" TRS and XLR Combo jack
Input Impedance 10k Ohms
Maximum Input Level +21dBu
Speaker Output Connector Neutrik® speakON®
Control Network Compatible w/ standard 100MB Ethernet
AUX Output Connector Balanced Euroblock 3.5 mm
AUX Output Maximum Level +21dBu
Remote Standby Contact Closure Euroblock 3.5 mm, close contact to GND for standby mode
Preset Recall Contact Closure Euroblock 3.5 mm, close contact to GND for preset 1-4 recall
Data Connection Euroblock 3.5 mm - Gnd, +18V, In, Out
Fault Condition Logic Outputs Euroblock 3.5 mm - 4 available
Remote DC Level Control Euroblock 3.5 mm - Gnd, CV, V+ per input
Attenuators (per channel) Front panel, software, offset link group, and remote. Fully off = Mute
Amplifier Protection Inrush current limitation, temperature monitoring, output over-power protection, mains fuses
Cooling Continuously variable temperature controlled axial fan(s)
Environmental 32–113 deg F, (0–45 deg, C) (non-condensing)
Power Requirements (@ 50/60Hz)
Nominal (Automatic Sensing SMPS) 120VAC; 240VAC
Operating Range 70–135VAC; 140–270VAC
Minimum Power-Up 85VAC; 170VAC
Dimensions (H x W x D) 3.5" (89 mm) x 19" (483 mm) x 16.84" (428 mm)
Shipping Dimensions (H x W x D) 22" (559 mm) x 24.5" (622 mm) x 5.25" (133 mm)
Net Weight 25.9 lbs (11.7 kg)
Shipping Weight 32.4 lbs (14.8 kg)