Furman F1500-UPS Uninterruptible Power Supply 1500VA Battery Backup and Power Conditioner
Usually arrives in 5-9 business days.
Furman F1000-UPS - 1000VA, 2RU Uninterruptible Power Supply
The Furman F1000-UPS: battery backup is designed exclusively for audio/video professionals and home theater aficionados.
The Furman F1000-UPS offers your system unparalleled battery back-up technology, created from the ground up to meet the exacting demands of the world's most sensitive audio, video and control systems!
Protection
Typical UPS systems feature antiquated surge suppression technologies that can cause as much damage and annoying lock-ups as they attempt to prevent. Only Furman offers battery back-up with our road-proven SMP non-sacrificial, zero ground contamination surge suppression technology, and EVS Extreme Voltage Shutdown. After all, the most robust battery can not function if the accompanying circuits are damaged. With Furman's F1000-UPS, you can expect years of trouble-free operation.
Filtration
Though many control devices are relatively immune to moderate levels of AC line noise, today's more sensitive devices (such as DLP projectors and line-level signal processors) certainly are not. High-definition technologies have pushed the resolution to levels so extreme that virtually any AC noise capable of coupling with your system's signal will distort, mask, or destroy the performance advantages we all strive so hard to capture and reproduce. Once again, the F1000-UPS is different. While other UPS devices feature AC line filters suitable for an I.T. closet, only Furman employs our exclusive Linear Filtering Technology (LiFT). This advanced noise filtering technology assures that today's ultra-wide dynamic range is maintained as it must be – pristine. Remember, less AC noise equals greater content, greater resolution, and higher definition.
Programmability and Control
Audio/video systems can vary greatly in their size and components, and as such, flexibility is needed in determining how a battery backup solution should function under different circumstances. Because of this, Furman has provided open source RS-232 control over two independent AC outlet banks, with a wide range of control features to interface with an existing automation solution. Dual programmable IR control allows the unit to send a shutdown command to remote components – no more expensive projector bulbs to replace in the event of a blackout.
* As with any battery back up system, the battery pack must be replaced periodically (typically every 2 years)
Typical Backup Components
Given the nature of battery backup technology, high-current audio and video components such as power amplifiers, powered subwoofers, and high-wattage displays are not recommended for use with the F1000-UPS. Not only will these components drain battery power quite rapidly, line impedance will be raised due to the F1000-UPS's (or any) AVR and AC to DC inverter, which can induce current compression and noticeably diminish performance with high-current A/V equipment. The following components are ideal for use with the F1000-UPS:
For power management of other components, Furman recommends Classic or Prestige Series Power Conditioners. For high-current components such as power amplifiers and powered subwoofers, solutions featuring Furman's exclusive Power Factor Technology are ideal.
Approximate Run Time, 1500VA **
Satellite Reciever or Cable Box = 80 Minutes
Control System + Media Server = 40 Minutes
Digital Mixing Console (24 channel) = 20 minutes
DAW Computer + Digital I/O + External Hard Drive + 24" LCD Monitor = 7 minutes
** These runtimes should be used as a guideline only and are dependent on device and usage.
| Input | |
|---|---|
| Voltage | 85 – 137 Vac |
| Frequency | 57 – 63 Hz |
| AC Power | |
| Surge Protection | Non-sacrifical SMP (Series Multi-Stage Protection) |
| Current Rating | 12 A |
| Over-Voltage Shutoff, Fast Rise | 150 ± 5V |
| Over-Voltage Shutoff, Slow Rise | 140 ± 5V |
| Noise Attenuation | 10 dB @ 10kHz, 40 dB @ 100 kHz, 50 dB @ 500kHz |
| Linear Attenuation | From 0.05 - 100 Ohms line impedance |
| Sensitive Mode Capture Range | 96 - 135V Automatic Voltage Regulation, |
| Sensitive Mode Output Range | 120V ± 5% Automatic Voltage Regulation, |
| Standard Mode Capture Range | 93 - 142V Automatic Voltage Regulation, |
| Standard Mode Output Range | 120V ± 10% Automatic Voltage Regulation, |
| UPS Output | |
| Voltage | 120 ± 5V True Sine Wave |
| Frequency | 60 Hz ± 1% |
| UPS Output Capacity | 1500VA, 900W @ 0.6pf |
| UPS Backup Time | 12 minutes at full-load, 32 minutes half-load |
| Transfer Time | < 4ms |
| Dimensions (H x W x D) | 3.5" (88.9 mm) x 17" (431.80 mm) x 13" (330.20 mm) |
| Dimensions With Rack Ears and Feet (H x W x D) | 4" (101.6 mm) x 19" (482.6 mm) x 13" (330.20 mm) |
| Weight | 72 lbs (32.65 kg) |