- Description
Details
Digi-Loop is definitely state-of-the-art – the first of its kind to maximize modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation and monitoring via laptop or tablet. DSP audio processing offers flexible, powerful software control of mixing, equalization, compression and more. Powerful Class D, pulse-width amplifiers maximize efficiency.
The Digi-Loop's amplifier design offers either single or dual 9.5 A rms loop outputs for perimeter loop(s), single array(s), dual loop, or phased-array configuration. A 70-100 V input provides connection to a distributed speaker/paging system, ensuring announcements are heard by loop users.
- Features
Features
- Network control - allows control and calibration of unit remotely with application software
- High continuous current 9.5 Arms (13.4 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- USB for firmware updates
- Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC and audio delay
- Power-save mode
- Adjustable output delay for multiple amps in large venues
- Fault warning and active protection against shorted or open circuits and overheating
- Loop fault relay output
- XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced
- Standard 1 RU, 19” rackmount
- Magnetic signal couples directly to devices equipped with telecoils (T-coils) such as hearing aids, cochlear implants, or optional loop receivers
- DL207 suitable for phased-array or dual-loop systems; DL107 suitable for perimeter loop or single array
- Phased-array mode automatically produces 90° phase shift in slave loop output
- Meets IEC 60118-4 system performance requirements when integrated into a correctly designed and installed system
- Test specification provided to IEC 62489-1 standard
- Meets ADA / ADAAG guidelines
- Specification
General Color Case: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue Fan Cooling Variable Speed, Temperature Controlled Power Supply Internal, Universal 100-240 VAC, 50/60 Hz, 200 Watt. Fuse: 5 x 20 mm, 5 A, 250 V
AC power plug is IEC 320-C14Heat Output @ 120 VAC Sleep State: 63 BTU/hr; Idle State: 84 BTU/hr; Driving two loops @ 9.5 A each: 638 BTU/hr Ethernet (1x) RJ-45; 10-100 MBps USB (1x) standard-B. USB 1.1, 2.0 or 3.0 supported Environment 0-35° C ( 32-95° F), 0-90% relative humidity Coverage Area 30,000 sq. ft. (2,786 sq. m.) (Perimeter Loops, 3:1 aspect ratio, both outputs driven)
18,000 sq. ft. (1,672 sq. m.) (Perimeter Loops, 1:1 aspect ratio, both outputs driven)Inputs Line Inputs (1x) 3-position terminal block, 10 kΩ input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB Mic/Line Inputs (1x) XLR 3-pin jack. Input impedance: 1.5 kΩ Mic, 10 kΩ Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V) 70-100V Input (1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems Outputs Line Outputs (1x) 3-position terminal block; loop-through of Mic/Line Input 1 & Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output Loop Output(s) (1x) 2-position terminal block per output Audio Output Delay Adjustable from 0 to 165 msec Headphone Output (1x) 1/4” stereo headphone jack, on front of unit. Monitored input or output selectable in menu Loop Fault Relay (1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC Loop Output Drive Voltage 16.1 Vrms (22.8 Vpk) continuous Rated Loop Output Current 9.5 Arms (13.4 Apk) per output Loop Resistance Range 0.5 Ω to 3.0 Ω (DC) Audio Rated Load 0.5 Ω DC with 135 µH inductance Frequency Response 45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.) Rated Loop THD <1 % at rated output current (1 kHz sine wave) Other Front Controls Front LCD display menu access/adjustment via control button/dial Adjustable Settings Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s) Internal Calibration Tools Test tone generator with pink noise, loop current adjustment/matching Other Features Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection Network Control & Firmware Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher. Firmware updates through USB only Warranty 5 years Approvals CE, UL, ULC, FCC, Industry Canada, RoHS, WEEE, CB scheme, RCM Standards Compliance This product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned. Test Specifications provided to the IEC 62489-1 standard Physical Rack Units 1 RU Rackmount Chassis Dimensions (W) 17" (431.8 mm) Dimensions (H x W x D) 1.75" (44.45 mm) x 19" (482.6 mm) x 10" (254 mm) Weight 9.2 lbs (4.2 kg) - Documents