- Description
Details
Slim (1U) 19”W rackmount panels feature 15A power outlets and a four step sequencer for time-delayed activation/deactivation of equipment directly plugged into the six (6) switched outlets. Three (3) additional outlets are unswitched (always on). Includes surge suppressor and alarm interface.
- Features
Features
- Power rating 120VAC 60Hz/15A with EMI/RFI filtering
- Terminates with 9 ft. cord and NEMA 5-15P plug
- Front rocker or key switch (on/off)
- One front and two rear unswitched outlets (always on); six rear switched outlets (activated by on/off switch)
- Four-step sequencer has a delay between steps that can be set between 0.5 and 10 seconds (screwdriver adjustable)
- Color coded LED status indicators
- Rear terminal block for connection to optional remote switches (momentary)
- Rear terminal block to allow system switches to be overridden for life safety system applications where fire code mandates an alarm interface
- Surge protector — UL1449 fourth edition and ANSI C62.41 compliant
- Defeats surges up to 72,000A
- Specification
Power Rating 120VAC, 60Hz, 15A 1800W Actuation Switch Front rocker or key switch with momentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (normally open) remote switches Alarm Interface Lock on, lock off and switch lock for alarm system or master control panel applications External Control Connections Plug-in barrier strip terminal blocks Termination 9 ft. attached cord with NEMA 5-15P plug EMI/RFI Filter 19dB @ 500kHz, 42dB @ 30MHz Front Receptacle One single unswitched (always on) Rear Receptacles Two single unswitched (always on)
One single switched (step 1)
One single switched (step 2)
One duplex switched (step 3)
One duplex switched (step 4)Step Delay 0.5–10 seconds between steps. Screwdriver adjustable Chassis Steel with black powder epoxy finish Agency Approvals ETL Listed in US and Canada to UL Standard 60065 “Audio, Video and Similar Electronic Apparatus” Three Stage Surge Protector Maximum Surge Current 72,000A (exceeds UL1449-4 6000V, 3000A) Initial Clamping Voltage 205V, UL rating 400V Endurance IEEE C62.41-1991, B3 (C1), Pulses (lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5,000 Transient Noise Reduction 25dB @ 100kHz, 50dB @ 1MHz Response Time Less than 5 nanoseconds Protection Mode Line to neutral, zero ground leakage UL1449-2 Adjunct Results 1000 surges, 6000 volts, 3000A, C1 and B3 waveforms (IEEE C62.41), No failures Diagnostic LEDs One green LED for each stage; All stages active when all lit Applicable Standards IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC 801-5) Dimensions (H x W x D) 1.75" (44.5 mm) x 19" (483 mm) x 9" (228.6 mm) Weight 12 lbs (5.44 kg) - Documents