AtlasIED ECM-20 20A AC Power Conditioner and Spike Suppressor
Usually arrives in 5-9 business days.
The Atlas Sound ECM-20SH 20A AC Power Conditioner and Spike Suppressor is a 120V 60Hz AC, 20A Single Housing (SH) Power Conditioner and AC Spike Suppressor that is designed to be used as a standalone unit or in conjunction with an Atlas Power Sequence controller, ECS-6RM or the ECS-3, up to 1000ft away.
The ECM-20SH is a 120V 60Hz AC, 20A Single Housing (SH) Power Conditioner and AC Spike Suppressor that is designed to be used as a standalone unit or in conjunction with an Atlas Power Sequence controller, ECS-6RM or the ECS-3, up to 1000ft away.
The ECM-20SH features noise filtering for removing unwanted Radio Frequency Interference (RFI) and EMI filters to reduce noise from Electromagnetic Interference (EMI) caused by items such as electric motors or switching power supplies. If an AC spike or surge occurs, the ECM-20SH also incorporates Clamping Suppression technology to prevent the unwanted energy from getting into your AV system. Other features include a Manual Bypass Switch, Incoming AC presence LED, Active LED and an AC Fault indicator. When interfaced with the ECS-6RM Sequencer controller, Extreme Voltage Shutdown Circuitry (EVS) is active, along with Voltage and Current status readings.
| Switched Outlets | Two, 20A |
|---|---|
| Spike & Surge Suppression | H-N, N-G, H-G |
| Manual Override | Slide switch |
| Extreme Voltage Shutdown | (EVS) Below 102V or Above 132V AC Line (When Used WithECS-6RM) |
| Connectors | 5 Position Phoenix Euro Block Style |
| Fuse Protection | 20A Slow Blow |
| DCV Remote Trigger | 5 – 24DCV |
| Remote Trigger | SPST Contact |
| Status Signals | Output for Voltage and Current Data (All signals are low voltageand low current) |
| Indicators | Incoming AC, Active, AC Fault |
| Power Cord | 9' (3M), 12-gauge NEMA 5-20P 125v AC plug |
| Current Rating | 20 amps |
| Operating Voltage | 102 to 132 VAC |
| High Voltage Surge Protection | Trigger at 133VAC, 1ms typically (When Used With ECS-6RM) |
| Spike & Surge Suppression | H-N, N-G, H-G |
| Low Voltage Protection | Trigger 101 VAC, 1ms typically (When Used With ECS-6RM) |
| Spike Protection Modes | Circuitry on incoming AC Mains. |
| Minimum Spike Clamping Voltage | 460 VRMS @ 3,000 amps |
| Maximum Spike Clamping Voltage | 6000v |
| Maximum Spike Clamping Response Time | 1 nanosecond |
| Spike Clamping Voltage @ 100A | 1250Vp for 20μs |
| Maximum surge current | 6,500 amps |
| Energy Rating @ 2ms | 600 Joules |
| Noise Attenuation EMI/RFI Sequencer | 10dB @ 10kHz, 40dB @ 100kHz, 100dB @ 10MHz |
| Temperature Range | 5° to 35° C |
| Humidity Range | 5% to 95% R.H. |
| Type | AC Power Conditioner & Suppressor Module |
| Power Requirements | 120V 60Hz |
| Power Consumption | .5W |
| RoHS Compliant | Yes |
| Chassis Finish | Black |
| Mounting | Side bracket adjustable |
| Dimensions (H x W x D) | 3.0" (76.2 mm) x 8.5" (215.9 mm) x 3.5" (88.9 mm) |
| Weight | 5.5 lbs (2.49 kg) |