- Description
Details
The SurgeX SA-82-AR IP-Enabled FlatPak Surge Eliminator provides premium protection for systems that rely on audio and video performance. Unlike common protection solutions, SurgeX's patented protection technology is non-sacrificial and eliminates surge energy up to 6,000 Volts, without producing harmful side effects such as ground contamination or common-mode disturbances that can degrade the performance of AV systems. With SurgeX, your connected equipment will be protected from destructive spikes, surges, and inductive transients that can cause disruptions and catastrophic damage.
The FlatPak is available in two configurations. The SA-82 provides premium protection for non-networked devices and the Axess Ready SA-82-AR offers remote IP control capabilities. This unique SA-82-AR solution gives technicians the ability to control any device that is not currently IP addressable and manage outlets including on/off, scheduling, AutoPing, and power cycling.- Features
Features
- Protects wall/ceiling equipment from power disturbances and catastrophic damage
- Provides 100% Fail-safe, non-sacrificial protection
- Eliminates surge energy up to 6,000 Volts/3,000 Amps
- Ultra compact < 5 lbs design can easily be integrated with wall/ceiling mounting systems
- Features SurgeX Series Mode® surge elimination technology
- Impedance Tolerant EMI/RFI Filtering, and Over Voltage Shutdown (with Auto Reset)
- Improves audio and video performance
- Axess Ready model offers Remote IP control capabilities
- Includes detachable IEC power cord and mounting brackets
- A-1-1 Certified
- Specification
Load Rating 8 Amps @ 120 Volts Power Requirement (no load) 10 Watts UL 1449-2 Adjunct Classification Test Results 1000 surges, 6000 Volts, 3000 Amps, C1 pulse, measured suppressed voltage 290 Volts, no failures EMI/RFI Filter, Normal Mode (50-ohm load) 40 dB@100 kHz; 50 dB@300 kHz; 50 dB@3 MHz; 50 dB@30 MHz EMI/RFI Filter, Common Mode (50-ohm load) 18 dB@300 kHz; 30 dB@1 MHz; 50 dB@5 MHz; 50 dB@20 MHz Maximum Applied Surge Pulse Joule Rating Unlimited, due to current limiting (8 x 20 μs) Maximum Applied Surge Pulse Voltage 6000 volts Maximum Applied Surge Pulse Current Unlimited, due to current limiting Endurance IEEE C62.41-1991 Category B3 (C1) Pulses m1 kV>500,000; 3 kV>10,000; 6 kV>1000 Overvoltage Shutdown 145 Volts (resume at 135 Volts) Temperature Range 5 - 35° C Humidity Range 5% to 95% R.H., non-condensing Dimensions (H x W x D) 11.375” (288.93 mm) x 1.813” (46.05 mm) x 7.63” (193.675 mm) Weight 4.75 lbs (2.16 kg) - Reviews
Write Your Own Review