SurgeX SA-82-AR IP-Enabled FlatPak Surge Eliminator
Usually arrives in 5-9 business days.
Featuring Series Mode surge elimination technology, SurgeX SA-82 FlatPak Surge Eliminator provides premium protection for systems that rely on audio and video performance. The patented protection technology is non-sacrificial and eliminates surge energy up to 6,000 Volts, without producing harmful side effects
Featuring Series Mode surge elimination technology, SurgeX SA-82 FlatPak Surge Eliminator provides premium protection for systems that rely on audio and video performance. Unlike common protection solutions, SurgeX's patented protection technology is non-sacrificial and eliminates surge energy up to 6,000 Volts, without producing harmful side effects such as ground contamination or common-mode disturbances that can degrade the performance of AV systems. With SurgeX, your connected equipment will be protected from destructive spikes, surges, and inductive transients that can cause disruptions and catastrophic damage.
The FlatPak is available in two configurations. The SA-82 provides premium protection for non-networked devices and the Axess Ready SA-82-AR offers remote IP control capabilities. This unique SA-82-AR solution gives technicians the ability to control any device that is not currently IP addressable and manage outlets including on/off, scheduling, AutoPing, and power cycling.
| Load Rating | 8 amps @ 120 volts |
|---|---|
| Power Requirement (no load) | 10 watts |
| UL 1449-2 Adjunct Classification Test Results | 1000 surges, 6000 volts, 3000 amps,C1 pulse, measured suppressed voltage 290 volts, no failures |
| Federal Guidelines | Grade A, Class 1, Mode 1 (CID A-A-55818) |
| EMI/RFI Filter, Normal Mode (50-ohm load) | 40 dB @ 100 kHz; 50 dB @ 300 kHz;50 dB @ 3 MHz; 50 dB @ 30 MHz |
| EMI/RFI Filter, Common Mode (50-ohm load) | 18 dB @ 300 kHz; 30 dB @ 1 MHz;50 dB @ 5 MHz; 50 dB @ 20 MHz |
| Maximum Applied Surge Pulse Joule Rating | Unlimited, due to current limiting (8 x 20 µs) |
| Maximum Applied Surge Pulse Voltage | 6000 volts (1.2 x 50 µs pulse),industry standard rating |
| Maximum Applied Surge Pulse Current | Unlimited, due to current limiting (8 x 20 µs) |
| Endurance | IEEE C62.41-1991 Category B3 (C1) |
| Pulses | 1 kv>500,000; 3 kv>10,000; 6 kv>1000 |
| Overvoltage Shutdown | 145 volts (resume at 135 volts) |
| Temperature Range | 5º to 35º C |
| Humidity Range | 5% to 95% R.H., non-condensing |
| Dimensions (H x W x D) | 1.75" (44.45 mm) x 5.31" (134.874 mm) x 9.06" (230.124 mm) |
| Weight | 3.4 lbs (1.54 kg) |
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.