Lowell ACSPR-RPC1-1509 Rackmount Panel w/Remote Power Control
Usually arrives in 5-9 business days.
The Lowell ACSPR-SEQ4-1509 is a slim 19”W rackmount panel featuring 15A power outlets and a four step sequencer for time-delayed activation/deactivation of equipment directly plugged into the six switched outlets.
Slim (1U) 19”W rackmount panels feature 15A power outlets and a four step sequencer for time-delayed activation/deactivation of equipment directly plugged into the six (6) switched outlets. Three (3) additional outlets are unswitched (always on). Includes surge suppressor and alarm interface.
| Power Rating | 120VAC, 60Hz, 15A 1800W |
|---|---|
| Actuation Switch | Front rocker or key switch with momentary contacts (normally open SPST) plus rear barrier strip termination blocks for momentary (normally open) remote switches |
| Alarm Interface | Lock on, lock off and switch lock for alarm system or master control panel applications |
| External Control Connections | Plug-in barrier strip terminal blocks |
| Termination | 9 ft. attached cord with NEMA 5-15P plug |
| EMI/RFI Filter | 19dB @ 500kHz, 42dB @ 30MHz |
| Front Receptacle | One single unswitched (always on) |
| Rear Receptacles | Two single unswitched (always on) One single switched (step 1) One single switched (step 2) One duplex switched (step 3) One duplex switched (step 4) |
| Step Delay | 0.5–10 seconds between steps. Screwdriver adjustable |
| Chassis | Steel with black powder epoxy finish |
| Agency Approvals | ETL Listed in US and Canada to UL Standard 60065 “Audio, Video and Similar Electronic Apparatus” |
| Three Stage Surge Protector | |
| Maximum Surge Current | 72,000A (exceeds UL1449-4 6000V, 3000A) |
| Initial Clamping Voltage | 205V, UL rating 400V |
| Endurance | IEEE C62.41-1991, B3 (C1), Pulses (lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5,000 |
| Transient Noise Reduction | 25dB @ 100kHz, 50dB @ 1MHz |
| Response Time | Less than 5 nanoseconds |
| Protection Mode | Line to neutral, zero ground leakage |
| UL1449-2 Adjunct Results | 1000 surges, 6000 volts, 3000A, C1 and B3 waveforms (IEEE C62.41), No failures |
| Diagnostic LEDs | One green LED for each stage; All stages active when all lit |
| Applicable Standards | IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC 801-5) |
| Dimensions (H x W x D) | 1.75" (44.5 mm) x 19" (483 mm) x 9" (228.6 mm) |
| Weight | 12 lbs (5.44 kg) |
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.