SurgeX CM-1115-RT Surge Eliminator (Discontinued)
Usually arrives in 5-9 business days.
The CM-1120-RT-AR features a revolutionary design that enables more rack space, it features compact solutions that can be mounted with plugs facing up or down for maximum convenience and flexibility. The SurgeX Space Saver products are 120V, 15/20 Amp AC power quality products.
The CM-1120-RT-AR features a revolutionary design that enables more rack space, it features compact solutions that can be mounted with plugs facing up or down for maximum convenience and flexibility. The SurgeX Space Saver products are 120V, 15/20 Amp AC power quality products incorporating SurgeX® Advanced Series Mode® power conditioning and surge protection. The surge protection is rated A-1-1, the highest standard of the Federal Commercial Item Description for Endurance. Several mounting options and receptacle configurations are available.
SurgeX ICE Inrush Current Elimination circuitry is incorporated into all of the Space Saver products. ICE® eliminates problems associated with inrush currents from large loads such as amplifiers. With SurgeX ICE® it is not necessary to take inrush currents into account when designing the AC power for a system, and special time-delay circuit breakers are not required: you only need to ensure that the steady-state currents of all products plugged into the Compact Mount or Versatile Rear Mount product are within the 15/20 Amp rating.
The Space Saver products incorporate contact closure and applied DC voltage remote control capabilities. Two or more CM or VM products can be connected together to provide control and power conditioning for larger systems. They can also control other SurgeX products with their auxiliary relay contacts and/or its 12V DC output.
A plug-in Phoenix terminal block on the rear panel accommodates the remote control connections and also the low-voltage outputs. There are three inputs which control power state; one 12V DC output; and one auxiliary relay providing normally-open contacts. The inputs can be controlled by an applied DC voltage from 5V to 30V, or by a contact closure. The inputs and 12V DC output are designed to withstand incorrect connections including polarity reversal and shorts.
| Operational Voltage Range | 90 to 150 Volts AC |
|---|---|
| Current rating | 15/20 Amps |
| Power Rating | 1,800/2,400 Watts |
| Maximum Load Inrush Energy | 1000 Joules total during power-up |
| Under-Voltage Shutdown | 90 V (resume at 100V) |
| Over-Voltage Shutdown | 145V (resume at 135V) |
| Surge Let-through Voltage | Zero let-through Voltage for a 6000 Volt surge |
| Meets Federal Guidelines | Grade A, Class 1, Mode 1 (CID A-A-55818) |
| EMI/RFI Filter, Normal Mode | 40 dB @ 100 KHz, 50dB @ 300 KHz, 50 dB @ 3 MHz,50 dB @ 30 MHz (50 Ohm load) |
| EMI/RFI Filter, Common Mode | 18dB @ 300 KHz, 30 dB @ 1 MHz, 50 dB @ 5 MHz,50 dB @ 20 MHz (50 Ohm load) |
| Maximum Applied Surge Voltage | 6,000 Volts |
| Maximum Applied Surge Current | Unlimited (due to current limiting) |
| Maximum Applied Surge Energy | Unlimited (due to current limiting) |
| Endurance | (C62.41-1991 category B3 pulses), 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000 |
| Number of Outlets | 2, 8, 18, or 24; Model Dependent |
| Remote Control Voltage | 5 to 30 Volts DC |
| Remote Control Current Draw | 4 mA maximum |
| Contact Closure Max. Resistance | 100 Ohms |
| Auxiliary Relay Contact Rating | 30 Volts DC at 1 Amp |
| 12 Volt Output Max. Current | 20 mA |
| Temperature Range | 5°C to 35°C |
| Humidity Range | 5% to 95% R.H. Non-condensing |
| Dimensions (H x W x D) | 5.66” (143.764 mm) x 4.95” (125.73 mm) x 9.50” (241.3 mm) |
| Weight | 8.5 lbs (3.854 kg) |
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.
Model #:
Usually arrives in 5-9 business days.