TOA ZM-9014 Remote Control Panel
Usually arrives in 5-9 business days.
The ZM-104A has been around for many years, and many experienced audio people have one. It can be used to troubleshoot a host of sound system problems, either stand-alone or with some additional gadgets.
It is equipped with a 3-step Range Selector which permits measuring of the impedance in the range of 5Ω to 100 kΩ. The 1kHz signal generator tone is perfect for checking the impedance of any input or output of an electronic audio component.
| Power Supply | AA (R6) battery x 4 (1.5 V DC x 4) |
|---|---|
| Current Consumption | 39 mA |
| Reading | Direct reading meter, unit: Ω |
| Measurement Range | x1 range: 5 Ω – 1 kΩ, x10 range: 50 Ω – 10 kΩ, x100 range: 500 Ω – 100 kΩ |
| Accuracy | ± 10% |
| Oscillation Frequency | 1,000 Hz ± 10 % |
| Battery Life | x1 range: 30 hours x10 range and x100 range: 60 hours (when continuously used) |
| Operating Temperature | -5 to +40 °C (23 to 104 °F) |
| Finish | ABS resin, black |
| Unit Dimensions (H x W x D) | 7.09" (180 mm) x 4.33" (110 mm) x 2.28" (58 mm) |
| Case Dimensions (H x W x D) | 8.66" (220 mm) x 4.72" (120 mm) x 2.48" (63 mm) |
| Weight | 1.54 lbs (700 g) (unit and carrying case) |